Reaction vessel with agitator
Level measurement during the production of chewing gum base
过程数据
测量任务:
Level measurement
测量点:
Reaction vessel
测量范围至:
7.5 m
介质:
Polyvinyl acetate
过程温度:
+120 … +150 °C
过程压力:
+1.2 … +1.5 bar
特殊挑战:
Low dielectric constant, turbulence
应用范围
Production of polyvinyl acetate – the base material for chewing gum – is carried out in a reaction vessel with a four stage agitator. The various raw materials begin to react when they are mixed by the agitator. To ensure smooth production, accurate level measurement is required.
您的获益
Reliable
Certified materials according to FDA and EC 1935/2004 regulations
Cost effective
Easy cleaning of the vessel
User friendly
Simple installation through existing ball valves
建议的产品

VEGAPULS 6X
Radar sensor for level measurement during the polymerization of chewing gum base in the reaction vessel
- Measuring results unaffected by agitator thanks to false signal suppression
- Strong focusing through small beam angle
- Measurement down to vessel bottom, even in media with low dielectric constant
量程 - 距离
120 m
过程温度
-196 ... 450 °C
过程压力
-1 ... 160 bar
关闭